• Rcm Concrete Chloride Migration Testing System
  • Rcm Concrete Chloride Migration Testing System
  • Rcm Concrete Chloride Migration Testing System
  • Rcm Concrete Chloride Migration Testing System
  • Rcm Concrete Chloride Migration Testing System
  • Rcm Concrete Chloride Migration Testing System

Rcm Concrete Chloride Migration Testing System

After-sales Service: 24hours, 24/Hrs Reply
Warranty: 1 Year
Detection Method: Electromigration Method (Rcm)
Test Indicators: Concrete Chloride Migration Coefficient
Test Channels: 6 Channels, 9 Channels, 12 Channels, 16 Channels
Output Current Range: 0~400 Ma
Customization:

Contact Supplier

Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
SY-RCM
Output Current Accuracy
+/-1mA
Temperature Accuracy
+/-1centigrade
Transport Package
Carton Case
Specification
SGS
Trademark
SAMYON
Origin
Cn
HS Code
903180
Production Capacity
100sets Per Month

Product Description

Rcm Concrete Chloride Migration Testing System
Executive Standard:

NT BUILD 492(Chloride Migration Coefficient from Non -Steady - State Migration Experiments)
EU - Project CHLORTEST G6RD -CT - 2002 - 00855
CEN TC 51(CEN TC 104)/WG12/TG5
Guide to Durability design ad Construction of Concrete Structures (CCES-01-2004)
 
Detection method: Electromigration method (RCM)
 
Test indicators: Concrete chloride migration coefficient
 
Application:
According to DuraCrete unsteady electromigration test theory, this method is to quantitatively evaluate the concrete resistance capacity to chloride ion diffusion, and to test the basic parameters with the design and durability of concrete structures and life assessment and prediction in the chloride ion erosion environment.
Test is acceptable for concrete specimens which are maximum aggregate size not more than 25mm (usually not more than 20mm) experimental production or from the core entities. Specimen data can be used as the basis for concrete durability mix design in chloride environment and concrete quality inspection and assessment.
  Rcm Concrete Chloride Migration Testing System
Technical parameters
1. Test channels: 6 channels, 9 channels, 12 channels, 16 channels optional
2. Output current range: 0~400 mA
3. Output current accuracy: +/-1mA
4. Temperature accuracy: +/-1centigrade
5. Output voltage: 0~60V (+/-0.1V) DC (adjustable)
6. Output Power Voltage: 220V+/-10 /50Hz AC
 
Product features:
1. 0 ~ 60 V adjustable voltage, short circuit auto-protect, single channel running time, the whole electric migration process is automatically controlled
2. Embedded computer control, power outages and power-down data storage, advanced technology, well-made, reliable performance, high accuracy
3. LCD display, with real-time display/print and analysis function, the computer screen can display the data at real-time, can be separated from Pc to use directly; after the testing, input the parameter can automatically calculate test results
4. Standard RS232 serial communications with fully automatic PC connection software can monitor the processing data; the PC can calculate the result and output the flux test report, and then print for analysis and archiving
5. Built-in analysis and calculation function; after testing, input parameters into the computer and then can automatically calculate test results
6. Automatic short circuit protection to avoid equipment damage
7. Imported material fixture, high accuracy, easy and smart to use
8. Can simultaneously test two groups (6), three (9), four (12) or five (16) concrete block one time
9. With the latest smart-in-one vacuum saturated machine
 
Rcm Concrete Chloride Migration Testing System
Rcm Concrete Chloride Migration Testing System
Rcm Concrete Chloride Migration Testing System

Experimental Methods
1. Cut the concrete sample into diameter 100mm, 50+/-2 mm thickness cylindrical test block
2. Clean the test block in the ultrasonic
3. After cleaning the sample, install it on specimen fixture, inject the test solution, connect the test host;
4. Open NJ-RCM chloride migration coefficient tester host for electromigration experiments
5. After the electromigration, split the sample along the axial, spray the silver nitrate on the split surface.
6. Input the data into the host, it will automatically calculate the channel migration coefficient
 
Specification:
1. Host dimension: 385*345*145(mm)
2. Host weight: 5kg
3. Host outside dimension: 530*200*420(mm)
4. Vacuum saturated machine weight: 32kg
5. Vacuum saturated machine dimension: 750*680*400(mm)
6. Accessories weight: 9kg
7. Accessories dimension: 610*270*260(mm)
8. Total weight: 46kg

Rcm Concrete Chloride Migration Testing System Rcm Concrete Chloride Migration Testing System Rcm Concrete Chloride Migration Testing System Rcm Concrete Chloride Migration Testing System Rcm Concrete Chloride Migration Testing System Rcm Concrete Chloride Migration Testing System Rcm Concrete Chloride Migration Testing System

Send your message to this supplier

*From:
*To:
avatar Mr. Jack Guo
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now