SY-R71,
Applications
used to test the degree of steel bar corrosion by electrochemical method, and to test the rebar location and distribution, and concrete coating thickness.
Standard
JGJ/T 152-2008 Technical specification for test of reinforcing steel bar in concrete GB 50204-2015 Code for quality acceptance of concrete structure construction GB/T 50344 -2004 Technical standard for inspection of building structure
Features
1. Two test modes: The potentiometry and gradient method is used to test steel-bar corrosion which suitable for different working field.
2. Permanent reference electrode: Saturated CuSO4 solution is sealed up completely in reference electrode. Field test keeps clean, simple and pollution-free operations.
3. Automatic measure environmental temperature. Instrument is with a environmental temperature module, it can measure, record and display temperature quickly, no need thermometers.
4. Single sensor: no need to change sensor in test, just switch it between high and low test range, so it can assure the precision of test data and the test depth.
5. Display test information on real-time.
6. Grid and section scan mode: it can display steel bar distribution and without concrete boundary limited.
7. Three-wheel steel-bar scan system can assure scan path along line and the precision of test data.
8. Can save test date. Convenient for data management.
9. Display test result intuitively by icon mode, The icon color is more dark, the steel-bar corrosion is more serious. User can observe the corrosion degree intuitively.
10. USB transmission. Data can be transmitted to computer for future process and analysis.
11. Powerful data process and analysis software, test data can be exported to word or excel for future process and analysis
Item | Name | Details | ||
1 | Test range | +/- 2000mV | ||
2 | Accuracy | +/- 1mV | ||
3 | Test point space | 1 ~99cm | ||
4 | Applicable rebar diameter | φ6mm to φ50mm | ||
5 | Low range coating thickness | 6mm to 90mm | ||
6 | High range coating thickness | 7mm to 180mm | ||
7 | Diameter test range | φ6mm to φ50mm | ||
8 | Rebar diameter error | +/-1 grade | ||
9 | Power | 6pcs No. 5 battery | ||
10 | Acceptable error for coating thickness test | Low range | High range | |
±1 | 6~59 | 7~79 | ||
±2 | 60~69 | 80~119 | ||
±4 | 70~90 | 120~180 | ||
11 | Applicable environmental |