It is suitable for field and lab marking thickness testing.
Main Specification:
Range: 0~±12.5 mm
Resolution:10um
Testing area: Minimum 50x80mm
Size:180x70x76mm (L×W ×H)
Weight: 880g
Instrument diagram: (1) Measuring head (2) switch (3) zero setting (4) positive-negative Switch
Simple Operation Steps
Start up: Press the ON/OFF button to start up.
Zero calibration: Put the instrument on the smooth surface, press the measuring head downward until can't down; meanwhile press the zero setting and the screen will be displayed to 0.00. If not displayed to 0.00, the up steps can be tried several times until the screen appears to 0.00MM and the value is adjusted to 0.00MM.
Test: The screen appears 0.00MM, which means the zero calibration is succeed. Put the measuring head on the marking line and then press down the measuring head until can't be pressed down; the value displayed on the screen is the thickness of the marking line. As showing in the picture below.