Customization: | Available |
---|---|
After-sales Service: | 24/Hrs Reply |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SY-261 (2008 Standard) Closed Cup Flash Point Tester
This instrument is designed and manufactured in accordance with the requirements stipulated in the National Standard GB/T 261-2008 "Binski-Martin Closed Cup Method for Flash Point Measurement". It is suitable for the determination of the Flash Point of petroleum product samples with the method prescribed in GB/T 261-2008.
The biggest characteristic of this instrument is that it fully meets the GB/T 261-2008 standard, and the instrument is classical. It can be used as a standard instrument for closed flash point detection in measuring and testing units.
Information for orders
Name |
Model |
Technical Features |
Standards |
Applicate Range |
Fully-automatic Pensky-martens Closed Cup Flash Point Tester |
SY-261D |
Fully-automatic |
GB/T261-2008 ISO2719 ASTM D93 |
It is suitable to determine the flash point of petroleum products,and with flash points above 40ºC and below 300ºC. |
Automatic Pensky-martens Closed Cup Flash Point Tester |
SY-261A |
Fully-automatic |
Ditto |
Ditto |
Closed Cup Flash Point Tester |
SY-261-1 |
Programmed temperature control,LCD display and A&B process |
Ditto |
Ditto |
SY-261 |
Manual |
Ditto |
Ditto |
|
Rapid Low Temperature Closed Cup Flash Point Tester |
SY-5208 |
Automatic finished except manual ignition |
GB/T 5208-2008 ISO 1523 ISO 3679 |
It is special for the less samples determination,such as colored paint,paint,adhesive,solvent,petroleum and other relevant products which flash point is -30ºC~50ºC. |
SY-5208D |
Automatic finished except manual ignition |
GB/T 5208-2008 ISO 1523 ISO 3679 |
It is special for the less samples determination,such as colored paint,paint,adhesive,solvent,petroleum and other relevant products which flash point is 0ºC~100ºC. |
Orders Comparision List
Model |
SY-261 |
SY-261-1 |
SY-261A |
SY-261D |
SY-5208 |
SY-5208D |
Standard |
GB/T261 |
GB/T261 |
GB/T261 |
GB/T261 |
GB/T5208 |
GB/T5208 |
Range |
(40~300)ºC |
(40~300)ºC |
(40~300)ºC |
(40~300)ºC |
(-30~50)ºC |
(0~100)ºC |
Repeatability |
2ºC(≤104ºC) 6ºC(>104ºC) |
2ºC(≤104ºC) 6ºC(>104ºC) |
Flash point ≤104ºC:error2ºC; Flash point>104ºC:error6ºC; |
2ºC(≤104ºC) 6ºC(>104ºC) |
Absolute difference between two experimental results<2ºC(Same operator) <3ºC(Different operators) |
|
Reproducibility |
4ºC(≤104ºC) 8ºC(>104ºC) |
4ºC(≤104ºC) 8ºC(>104ºC) |
Flash point ≤104ºC:error4ºC; Flash point>104ºC:error8ºC; |
4ºC(≤104ºC) 8ºC(>104ºC) |
||
Automatic up/down |
No |
No |
Yes |
Yes |
No |
No |
With microprinter |
No |
No |
Yes |
Yes |
Yes |
Yes |
Display |
No |
Digital display |
Yes |
Yes |
Yes |
Yes |
Communication port |
No |
No |
No |
Yes |
No |
No |
Sample |
Standard oil cup |
Standard oil cup |
Standard oil cup |
Standard oil cup |
2mL |
2mL |
Automatic detect |
No |
Automatic heating up |
Yes |
Yes |
Yes |
Yes |
I.Standards and scope of application
Standard:GB/T 261-2008 ASTM D93
Scope:with flash points above 40ºC
II.Technical Parameters
Heater power |
600w |
Stirring speed |
As per the reiquirement of GB/T261-2008; |
a.90~120 RPM for process A; b.240~260 RPM for process B; |
|
Up-temperature speed |
(1~12)ºC/min; |
Power supply |
AC(220±10%)V,50Hz. |