Ndj-1f Brookfield Viscometer Method Brookfield Viscometer

Product Details
Customization: Available
After-sales Service: 24/Hrs Reply
Warranty: 1 Year, 1 Year
Manufacturer/Factory, Trading Company
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1200000 RMB
Plant Area
101~500 square meters
  • Ndj-1f Brookfield Viscometer Method Brookfield Viscometer
  • Ndj-1f Brookfield Viscometer Method Brookfield Viscometer
  • Ndj-1f Brookfield Viscometer Method Brookfield Viscometer
  • Ndj-1f Brookfield Viscometer Method Brookfield Viscometer
  • Ndj-1f Brookfield Viscometer Method Brookfield Viscometer
  • Ndj-1f Brookfield Viscometer Method Brookfield Viscometer
Find Similar Products

Basic Info.

Model NO.
Ndj-1f
Structure
Portable
After-Sales Service
24/Hrs Reply
Measurement Range
25 MPa.S~1*107 MPa.S
Measuring Accuracy
+/-2% (F.S)
Spindles
No.21. 27. 28 and 29 Spindles
Rotation Speed
0.5, 1, 2, 5, 10, 20, 50 Rpm
Temperature Control Range
25 Oc~200 Oc
Temperature Control Accuracy
+/-0.1 Oc
Spindle Speed
0.1~200 Rpm
Transport Package
Carton Case
Specification
SGS
Trademark
SAMYON
Origin
Cn
HS Code
903180
Production Capacity
100sets Per Month

Product Description

I. Summary
The instrument is designed and made according to the requirement of the T0625 "Asphalt Brookfield Rotation Viscosity Test (Brookfield Viscometer Method)" in the Industry Standard of People's Republic of China JTJ052 Specifications and Test Methods of Bitumen and Bituminous Mixtures for Highway Engineering. It is suitable to determine the absolute viscosity of the Newtonian liquids and the apparent viscosity of the non-Newtonian liquids.
The instrument adopts the advanced mechanical design technology, manufacturing techniques and microcomputer technology for temperature control, data collection, and data processing. It takes a white background light, ultra bright LCD screen as display screen. The instrument also equips a pin type micro-printer for data output. The measurement data can be shown on the display screen in real time and printed out through the printer. In addition, the instrument can connect to the PC through the RS232 communication interface.
The instrument has the characteristics of high measurement sensitivity, reliable results and delicate shape, as well as convenience to be operated. It can be widely used to determine the viscosity of various liquids such as asphalt, hot sol, paraffin, high polymer and so on.
 
II. Main technical specifications and parameters
Measurement range 25 mPa·s~1×107 mPa·s ( If choosing the No.30 spindle, the measurement range can extend to 2×107 mPa·s)
Spindle No. 21, 27, 28, 29 total four types of spindles (the No.30 is optional)
Spindle speed 0.1~200 RPM, continuously speed regulation (With 12 grades of speed)
Measurement error ±2% (F·S), choosing the No.30 spindle, it will be ±3% (F·S)
Temperature control range 25 ºC~200 ºC
Temperature control accuracy ±0.1 ºC
Sample cylinder cubage 20 ml
Power supply AC 220 V±10%, 50 Hz
Ambient temperature 5 ºC~35 ºC (when the control temperature of the heater is close to the ambient temperature, turn on the air conditioner to allow the ambient temperature is approximately 5 ºC lower than the control temperature of the heater);
Relative humidity ≤80%

1. Measurement range: 25 mPa·s~1×107 mPa·s ( If choosing the No.30 spindle, the measurement range can extend to 2×107 mPa·s)
2. Spindle: No. 21, 27, 28, 29 total four types of spindles (the No.30 is optional)
3. Spindle speed: 0.1~200 RPM, continuously speed regulation (With 12 grades of speed)
4. Measurement error: ±2% (F·S), choosing the No.30 spindle, it will be ±3% (F·S)
5. Temperature control range: 25 ºC~200 ºC
6. Temperature control accuracy: ±0.1 ºC
7. Sample cylinder cubage: 20 ml
8. Power supply: AC 220 V±10%, 50 Hz
9. Ambient temperature: 5 ºC~35 ºC (when the control temperature of the heater is close to the ambient temperature, turn on the air conditioner to allow the ambient temperature is approximately 5 ºC lower than the control temperature of the heater);
10. Relative humidity: ≤80%
 
Ndj-1f Brookfield Viscometer Method Brookfield Viscometer
Ndj-1f Brookfield Viscometer Method Brookfield Viscometer
 
Ndj-1f Brookfield Viscometer Method Brookfield Viscometer
Ndj-1f Brookfield Viscometer Method Brookfield Viscometer

Ndj-1f Brookfield Viscometer Method Brookfield ViscometerNdj-1f Brookfield Viscometer Method Brookfield ViscometerNdj-1f Brookfield Viscometer Method Brookfield ViscometerNdj-1f Brookfield Viscometer Method Brookfield ViscometerNdj-1f Brookfield Viscometer Method Brookfield ViscometerNdj-1f Brookfield Viscometer Method Brookfield ViscometerNdj-1f Brookfield Viscometer Method Brookfield ViscometerNdj-1f Brookfield Viscometer Method Brookfield Viscometer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier